Title :
A new detection method for capacitive micromachined ultrasonic transducers
Author :
Ergun, Arif Sanli ; Temelkuran, Burak ; Ozbay, Ekmel ; Atalar, Abdullah
Author_Institution :
Edward L. Ginzton Lab., Stanford Univ., CA, USA
fDate :
7/1/2001 12:00:00 AM
Abstract :
Capacitive micromachined ultrasonic transducers (cMUT) have become an alternative to piezoelectric transducers in the past few years. They consist of many small circular membranes that are connected in parallel. In this work, we report a new detection method for cMUTs. We model the membranes as capacitors and the interconnections between the membranes as inductors. This kind of LC network is called an artificial transmission line. The vibrations of the membranes modulate the electrical length of the transmission line, which is proportional to the frequency of the signal through it. By measuring the electrical length of the artificial line at a high RF frequency (in the gigahertz range), the vibrations of the membranes can be detected in a very sensitive manner. For the devices we measured, we calculated the minimum detectable displacement to be in the order of 10/sup -5/ /spl Aring///spl radic/Hz with a possible improvement to 10/sup -7/ /spl Aring///spl radic/Hz.
Keywords :
capacitive sensors; micromachining; ultrasonic transducers; LC network; artificial transmission line; cMUT; capacitive micromachined ultrasonic transducers; circular membranes; detection method; electrical length; minimum detectable displacement; Biomembranes; Capacitors; Electric variables measurement; Frequency measurement; Inductors; Length measurement; Piezoelectric transducers; Transmission line measurements; Ultrasonic transducers; Vibration measurement;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on