Abstract :
Converters employing IGCTs usually require di/dt snubber and over voltage protection (OVP) circuit for the protection of IGCTs. In these IGCT-based converters, loss of conventional di/dt snubber and OVP clamp circuit is relatively high. To reduce this loss of conventional di/dt snubber and OVP clamp circuit, this paper proposes a flyback-type di/dt snubber for IGCT-based converters. This flyback-type di/dt snubber simply consists of a flyback-type transformer and a clamp diode. The proposed circuit reduces loss and simplifies conventional di/dt snubber by adopting the flyback-type transformer. The loss analysis of conventional di/dt snubber and OVP clamp circuit is performed for the neutral point clamped (NPC) 3-level back-to-back type voltage source converter (VSC) supplied from grid voltage of 6.9kV. At maximum, the proposed flyback-type di/dt snubber can save the loss (34kW, 0.49%) of conventional snubber circuit in a 7MW back-to-back 3L-NPC VSCs. The proposed snubber has a fewer number of components and improved efficiency.
Keywords :
power transformers; snubbers; thyristor convertors; wind turbines; 3-level back-to-back type voltage source converter; IGCT-based converters; OVP clamp circuit; back-to-back 3L-NPC VSC; clamp diode; flyback-type di/dt snubber; flyback-type transformer; neutral point clamped voltage source converter; over voltage protection; voltage 10 kV; wind turbines; Clamps; Inductance; Inductors; Power conversion; Snubbers; Switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2014 IEEE
Conference_Location :
Pittsburgh, PA
Type :
conf
DOI :
10.1109/ECCE.2014.6954029
Filename :
6954029
Link To Document :
بازگشت