DocumentCode
1513255
Title
Effects of nonsinusoidal voltage on the operation performance of a three-phase induction motor
Author
Lee, Ching-Yin ; Lee, Wei-Jen
Author_Institution
Dept. of Electr. Eng., Nat. Taipei Univ., Taiwan
Volume
14
Issue
2
fYear
1999
fDate
6/1/1999 12:00:00 AM
Firstpage
193
Lastpage
201
Abstract
This paper uses a real load test to investigate the effects of each order of harmonic from 2 to 13 under various voltage distortion factors (VDF) on the performance of a three-phase induction motor. The investigation includes input current, power factor, efficiency, temperature rise and their impacts on the consumers and utility companies. Since the life span of the motors is dramatically affected by the temperature rise, a new derating factor is proposed in this paper. Besides, the impacts of harmonics on electricity energy, consumers and the life span of a motor are also discussed, respectively. Finally, it is strongly suggested that even order harmonics and harmonics having an order below 5 should be considered in related regulations of harmonics control and limits
Keywords
harmonic distortion; induction motors; machine testing; power system harmonics; derating factor; efficiency; input current; nonsinusoidal voltage; operation performance; power factor; real load test; temperature rise; three-phase induction motor; voltage distortion factors; Control systems; DC motors; Distortion measurement; Induction motors; Power system harmonics; Servomotors; Signal analysis; System testing; Torque control; Voltage measurement;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.766983
Filename
766983
Link To Document