Title :
Effects of unbalanced voltage on the operation performance of a three-phase induction motor
Author_Institution :
Dept. of Electr. Eng., Nat. Taipei Univ. of Technol., Taiwan
fDate :
6/1/1999 12:00:00 AM
Abstract :
This paper uses a real load test to investigate the effects of an unbalanced voltage supply on an induction motor´s performance. Based upon various experiments, including: (1) cases with the same unbalance voltage factor but different unbalanced voltages; (2) cases with only one unbalanced voltage but different degrees of unbalance; and (3) cases with the same positive-sequence voltage but different negative-sequence voltages, the importance of the positive-sequence voltage in the motor´s apparent performance and of the negative-sequence voltage in the hidden damage are pointed out. Finally, it is strongly suggested that the related regulations, and a motor´s derating factor and temperature rise curves should be based on not only a voltage unbalance factor, but also the magnitude of the positive-sequence voltage
Keywords :
harmonic distortion; induction motors; machine testing; power system harmonics; derating factor; operation performance; positive-sequence voltage; real load test; temperature rise curves; three-phase induction motor; unbalance voltage factor; unbalanced voltage; Fuses; Induction motors; Paper technology; Power systems; Power transmission lines; Protection; Reactive power; Temperature; Testing; Voltage;
Journal_Title :
Energy Conversion, IEEE Transactions on