• DocumentCode
    1513741
  • Title

    Comments on "A passivity-based method for induction motor control" [with reply]

  • Author

    Chiasson, J. ; Novotnak, R.T. ; Gokdere, L.U. ; Simaan, Marwan A.

  • Author_Institution
    ABB Daimler-Benz Transportation, Pittsburgh, PA, USA
  • Volume
    46
  • Issue
    3
  • fYear
    1999
  • fDate
    6/1/1999 12:00:00 AM
  • Firstpage
    669
  • Lastpage
    671
  • Abstract
    In the paper by L.U. Gokdere and M.A. Simaan (see ibid., vol. 44, p.688-95, 1997), a comparison is made between a passivity based controller and an input-output linearization controller. We point out that this comparison is not valid as the same trajectory was not used for both controllers. The original authors reply to this comment pointing out that there is experimental evidence demonstrating the benefits of the passivity-based controller developed for induction motors. These include closer tracking of the same mechanical trajectory, and less sensitivity to magnetic saturation, when compared with the input-output linearization controller.
  • Keywords
    control system analysis; induction motors; machine control; induction motor control; input-output linearization controller; mechanical trajectory tracking; passivity based controller; passivity-based method; trajectory; Acceleration; Cameras; Induction motors; Robot control; Robot kinematics; Robot sensing systems; Robot vision systems; Robotics and automation; Servomechanisms; Trajectory;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/41.767079
  • Filename
    767079