    DC impedance modelling of a MMC-HVDC system for DC voltage ripple prediction under a single-line-to-ground fault

  • Author

    Xiaojie Shi ; Zhiqiang Wang ; Bo Liu ; Yalong Li ; Tolbert, Leon M. ; Wang, F.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., Univ. of Tennessee, Knoxville, TN, USA
  • fYear
    2014
  • fDate
    14-18 Sept. 2014
  • Firstpage
    5339
  • Lastpage
    5346
  • Abstract
    This paper investigates the prediction of the second order dc voltage ripple in a modular multilevel converter (MMC) based point-to-point high-voltage direct-current (HVDC) system when the rectifier station suffers a single-line-to-ground (SLG) fault. Under this unbalanced condition, the second order dc voltage ripple will transfer to the healthy inverter station and can lead to a potential output voltage distortion. To accurately predict the dc voltage ripple distribution, the equivalent dc side impedances of the MMC inverter station with and without circulating current control are derived separately. It is shown that the MMC inverter station can be regarded as a series connected R-L-C branch in both cases, and the branch values are independent of the adopted current and power control schemes. In addition, long cables with small capacitance and large inductance help to mitigate the voltage ripple in the inverter station. The circulating current control, acting as an active resistance, effectively damps the possible resonance around 120 Hz between the dc cable and the MMC inverter. However, due to the higher equivalent dc impedance, the amplitude of the 2nd order dc voltage ripple in the inverter station is increased. Simulation results from a MMC based HVDC system, and experimental results from a three-phase MMC inverter are provided to support the theoretical analysis.
  • Keywords
    HVDC power convertors; HVDC power transmission; electric current control; invertors; power control; power transmission faults; rectifier substations; DC impedance modelling; DC voltage ripple distribution; DC voltage ripple prediction; MMC inverter station; MMC-HVDC system; SLG fault; current control; equivalent DC side impedance; modular multilevel converter; point-to-point high-voltage direct-current system; power control scheme; rectifier station; series connected R-L-C branch; single-line-to-ground fault; voltage distortion; voltage ripple mitigation; Capacitance; Current control; Impedance; Inductance; Inverters; Rectifiers; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2014 IEEE
  • Conference_Location
    Pittsburgh, PA
  • Type

    conf

  • DOI
    10.1109/ECCE.2014.6954133
  • Filename
    6954133