DocumentCode :
151391
Title :
Optimised operation mode for the Hexverter topology based on adjacent compensating power
Author :
Karwatzki, Dennis ; Baruschka, Lennart ; von Hofen, Malte ; Mertens, Axel
Author_Institution :
Inst. for Drive Syst. & Power Electron., Leibniz Univ. Hannover, Hannover, Germany
fYear :
2014
fDate :
14-18 Sept. 2014
Firstpage :
5399
Lastpage :
5406
Abstract :
The recently proposed Hexverter topology belongs to the group of modular multilevel direct AC/AC converters. For its operation, a so-called adjacent compensating power is essential. This paper introduces a new method for composing the adjacent compensating power, which optimises the efficiency. The importance of the adjacent compensating power for branch energy control is shown and the differences between the old and the new method are lined out. Functionality is verified by simulation and experimental results.
Keywords :
AC-AC power convertors; network topology; Hexverter topology; adjacent compensating power; modular multilevel direct AC/AC converters; optimised operation mode; Equations; Reactive power; Switches; Three-dimensional displays; Topology; Voltage control; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2014 IEEE
Conference_Location :
Pittsburgh, PA
Type :
conf
DOI :
10.1109/ECCE.2014.6954141
Filename :