DocumentCode :
1515723
Title :
Artery-vein separation via MRA-An image processing approach
Author :
Lei, Tianhu ; Udupa, Jayaram K. ; Saha, Punam K. ; Odhner, Dewey
Author_Institution :
Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA, USA
Volume :
20
Issue :
8
fYear :
2001
Firstpage :
689
Lastpage :
703
Abstract :
Presents a near-automatic process for separating vessels from background and other clutter as well as for separating arteries and veins in contrast-enhanced magnetic resonance angiographic (CE-MRA) image data, and an optimal method for three-dimensional visualization of vascular structures. The separation process utilizes fuzzy connected object delineation principles and algorithms. The first step of this separation process is the segmentation of the entire vessel structure from the background and other clutter via absolute fuzzy connectedness. The second step is to separate artery from vein within this entire vessel structure via iterative relative fuzzy connectedness. After seed voxels are specified inside the artery and vein in the CE-MRA image, the small regions of the bigger aspects of artery and vein are separated in the initial iterations, and further detailed aspects of artery and vein are included in later iterations. At each iteration, the artery and vein compete among themselves to grab membership of each voxel in the vessel structure based on the relative strength of connectedness of the voxel in the artery and vein. This approach has been implemented in a software package for routine use in a clinical setting and tested on 133 CE-MRA studies of the pelvic region and two studies of the carotid system from 6 different hospitals. In all studies, unified parameter settings produced correct artery-vein separation. When compared with manual segmentation/separation, the authors´ algorithms were able to separate higher order branches, and therefore produced vastly more details in the segmented vascular structure. The total operator and computer time taken per study is on the average about 4.5 min. To date, this technique seems to be the only image processing approach that can be routinely applied for artery and vein separation.
Keywords :
biomedical MRI; blood vessels; image enhancement; image segmentation; iterative methods; medical image processing; software packages; 4.5 min; MRA; absolute fuzzy connectedness; artery-vein separation; clutter; contrast-enhanced magnetic resonance angiographic image data; initial iterations; iterative relative fuzzy connectedness; later iterations; medical diagnostic imaging; near-automatic process; seed voxels; unified parameter settings; vessels-background separation; Arteries; Data visualization; Image processing; Image segmentation; Iterative algorithms; Magnetic resonance; Separation processes; Software packages; Software testing; Veins; Algorithms; Arteries; Carotid Arteries; Contrast Media; Fuzzy Logic; Humans; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Magnetic Resonance Angiography; Pelvis; Veins;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.938238
Filename :
938238
Link To Document :
بازگشت