Title :
A microprocessor-based self-adjusting system for integral cycle power control of RL loads
Author :
El-Bolek, H.M. ; Abd-el-hamid, Samir S.
Author_Institution :
Fac. of Eng. & Technol., Helwan Univ., Cairo, Egypt
fDate :
4/1/1990 12:00:00 AM
Abstract :
A microprocessor-based method is introduced to eliminate the DC current offset component in integral cycle-controlled resistive and inductive (RL) loads. After choosing a suitable initial value of the triac (or thyristor) firing angle α (90° for best results), the microprocessor adjusts α, bringing it closer to the load power factor angle φ at every burst of conduction. A firing angle that is almost equal to φ is reached after few bursts. This eliminates the undesired DC current offset component. The use of the microprocessor allows a simpler and more flexible solution to the problem than conventional techniques
Keywords :
microcomputer applications; power control; self-adjusting systems; DC current offset component; RL loads; inductive loads; integral cycle power control; load power factor angle; microprocessor-based self-adjusting system; resistive loads; thyristor firing angle; Circuits; DC motors; Lighting control; Microprocessors; Power control; Radio control; Reactive power; Temperature control; Thyristors; Voltage control;
Journal_Title :
Industrial Electronics, IEEE Transactions on