• DocumentCode
    1518341
  • Title

    Stability and characteristics of large CZT coplanar electrode detectors

  • Author

    Pérez, José M. ; He, Zhong ; Webe, D.

  • Author_Institution
    CIEMAT, Madrid, Spain
  • Volume
    48
  • Issue
    3
  • fYear
    2001
  • fDate
    6/1/2001 12:00:00 AM
  • Firstpage
    272
  • Lastpage
    277
  • Abstract
    The single polarity charge sensing method based on coplanar grid electrodes has demonstrated promising results on CZT detectors having volumes of ~1 cm3. This paper presents the performance of two coplanar grid CZT detectors having dimensions of 1.5×1.5×1.0 cm2, among the largest CZT spectrometers that have been reported. Energy resolutions of 2.3% and 2.0 % full-width half-maximum were obtained on the two detectors at 662 keV using simple analog techniques. Further improvement is achievable with depth sensing and digital pulse processing techniques. Other detector characteristics, critical to practical application of these devices, are reported. This includes the stability of detector response over a period of several months and the variation of detector performance in environments having high gamma radiation fluxes and a range of counting rates
  • Keywords
    electrodes; gamma-ray spectrometers; semiconductor counters; 662 keV; CZT spectrometers; CdZnTe; coplanar grid CZT detectors; depth sensing; digital pulse processing; energy resolution; full-width half-maximum; gamma ray; single polarity charge sensing method; Electrodes; Energy resolution; Gamma ray detection; Gamma ray detectors; Helium; Preamplifiers; Radiation detectors; Semiconductor radiation detectors; Spectroscopy; Stability;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.940064
  • Filename
    940064