Title :
The port card for the silicon vertex detector upgrade of the Collider Detector at Fermilab
Author :
Andresen, J. ; Bishai, M. ; Cancelo, G. ; Derylo, G. ; Ely, R. ; Franzen, J. ; Garcia-Sciveres, M. ; Gotra, Y ; Kwarciany, R. ; Perez, J. ; Shenai, A. ; Shepard, P. ; Treptow, K. ; Zimmermann, S.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
fDate :
6/1/2001 12:00:00 AM
Abstract :
The collider detector at Fermilab is approaching the completion of the silicon vertex detector upgrade for Run II. The port card is a Beryllia multichip module developed to control, read out, and regulate power for the silicon strip readout chips. It has two radiation hard application-specific integrated circuits, parallel fiber-optic transmitters, and voltage regulators. It resides 14 cm from the accelerator beam inside the tracking volume. The function and location of the port card impose severe constraints on its design. This paper presents the port card and describes the adopted solutions to address the main design issues, as well as the result of many characterization tests
Keywords :
application specific integrated circuits; nuclear electronics; readout electronics; silicon radiation detectors; voltage control; ASIC; Beryllia multichip module; Si; Si vertex detector upgrade; fiber-optic transmitters; port card; voltage regulators; Application specific integrated circuits; Detectors; Multichip modules; Particle beams; Regulators; Silicon; Strips; Testing; Transmitters; Voltage;
Journal_Title :
Nuclear Science, IEEE Transactions on