Design and performance of collimated coincidence point sources for simultaneous transmission measurements in 3-D PET
Author
Watson, C.C. ; Eriksson, L. ; Casey, M.E. ; Jones, W.F. ; Moyers, J.C. ; Miller, S. ; Hamill, J. ; Van Lingen, A. ; Bendriem, B. ; Nutt, R.
Author_Institution
CTI PET Syst. Inc., Knoxville, TN, USA
Volume
48
Issue
3
fYear
2001
fDate
6/1/2001 12:00:00 AM
Firstpage
673
Lastpage
679
Abstract
The authors have implemented a simultaneous emission-transmission measurement for three-dimensional positron emission tomography (3-D PET) using a collimated coincidence point source design employing a fast, dedicated, reference detector close to the transmission source. This design reduces the effects of randoms, scatter, dead time, and sensitivity loss on the emission data compared to previous implementations. It also greatly reduces the effect of emission contamination of the transmission data compared to the use of rod sources. Here, the authors present performance characterizations of this measurement technique on both the Siemens/CTI ECAT ART and PET/SPECT tomographs. The main effect of the transmission sources on the emission measurement is an increased randoms rate, which lends to a 10-25% reduction in NECR at specific activities >2 kBq/mL in a 21-cm-diameter phantom on the PET/SPECT. Emission contamination effects on the transmission measurement are estimated to be less than 1% for up to 20 kBq/mL in a 21-cm phantom on the PET/SPECT. Both the emission and transmission NECR are dominated by the effects of randoms. Considering the effects of both emission and transmission noise on the final corrected image, it appears that 3-6 kBq/mL of emitter concentration is an optimal imaging range for simultaneous acquisitions. The authors present the first images of a normal volunteer using this system on a Siemens/CTI PET/SPECT tomograph
Keywords
gamma-ray absorption; positron emission tomography; radioactive sources; 21 cm; 3-D PET; Siemens/CTI PET/SPECT tomograph; collimated coincidence point sources design; collimated coincidence point sources performance; dead time; emission contamination; fast dedicated reference detector; medical diagnostic imaging; normal volunteer; nuclear medicine; randoms; scatter; sensitivity loss; simultaneous transmission measurements; transmission data; Collimators; Contamination; Detectors; Imaging phantoms; Measurement techniques; Pollution measurement; Positron emission tomography; Scattering; Standards publication; Subspace constraints;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.940145
Filename
940145
Link To Document