DocumentCode :
1518944
Title :
Four-dimensional affine registration models for respiratory-gated PET
Author :
Klein, Gregory J. ; Reutter, Bryan W. ; Huesman, Ronald H.
Author_Institution :
Center for Functional Imaging, California Univ., Berkeley, CA, USA
Volume :
48
Issue :
3
fYear :
2001
fDate :
6/1/2001 12:00:00 AM
Firstpage :
756
Lastpage :
760
Abstract :
The heart position shifts considerably due to motion associated with the respiratory cycle, and this motion can degrade the image quality of cardiac-gated positron emission tomography (PET) studies. One method to combat this motion-induced blur is a respiratory-gated acquisition followed by recombination of registered image volumes using a rigid-body motion assumption; however, nonrigid deformation of the heart from respiratory motion may reduce the effectiveness of this procedure. We have investigated a 12-parameter global affine motion model for registration of different respiratory gates in an end-diastolic cardiac PET sequence. To obtain robust estimates of motion, a four-dimensional registration model was devised that encouraged smoothly varying motion between adjacent respiratory time frames. Registration parameters were iteratively calculated using a cost function that combined a least squares voxel difference measure with a penalty obtained from a prediction prior. The prior was calculated from adjacent time frames assuming constant velocity and an affine model. After registration, the principal extension ratios were calculated to measure the degree of nonrigid motion. In data from ten subjects, extension ratios of over 5% were common, indicating that an affine model may provide better registrations and in turn, better motion-corrected composite volumes than could a technique restricted to the six-parameter rigid body assumption
Keywords :
cardiology; image registration; medical image processing; pneumodynamics; positron emission tomography; 12-parameter global affine motion model; adjacent respiratory time frames; adjacent time frames; affine model; cardiac-gated positron emission tomography; constant velocity; cost function; end-diastolic cardiac PET sequence; extension ratios; four-dimensional affine registration models; heart position; image quality; iterative calculation; least squares voxel difference measure; motion; motion-corrected composite volumes; motion-induced blur; nonrigid deformation; nonrigid motion; penalty; prediction prior; principal extension ratios; registered image volume recombination; registration parameters; respiratory cycle; respiratory motion; respiratory-gated PET; respiratory-gated acquisition; rigid-body motion; six-parameter rigid body assumption; smoothly varying motion; Computed tomography; Cost function; Degradation; Heart; Image quality; Least squares methods; Motion compensation; Motion estimation; Positron emission tomography; Robustness;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.940159
Filename :
940159
Link To Document :
بازگشت