• DocumentCode
    1519013
  • Title

    The effect of humidity on the calibration of precision air capacitors

  • Author

    Ford, L.H.

  • Volume
    95
  • Issue
    48
  • fYear
    1948
  • fDate
    12/1/1948 12:00:00 AM
  • Firstpage
    709
  • Lastpage
    712
  • Abstract
    The paper describes measurements, at a frequency of 1 000 c/s, of the capacitance changes in air capacitors due to moisture in the atmosphere. It is shown that these changes may be considerably in excess of those due to the alterations in the permittivity of the air. Over the range of relative humidity 30¿65% the total change in capacitance can be about 3 parts in 10 000 at room temperatures. The full advantage of the otherwise high stability of a precision air capacitor is lost when this effect is ignored.
  • Keywords
    capacitance measurement; capacitors;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers - Part II: Power Engineering, Journal of the Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/ji-2.1948.0199
  • Filename
    5297007