DocumentCode
1519013
Title
The effect of humidity on the calibration of precision air capacitors
Author
Ford, L.H.
Volume
95
Issue
48
fYear
1948
fDate
12/1/1948 12:00:00 AM
Firstpage
709
Lastpage
712
Abstract
The paper describes measurements, at a frequency of 1 000 c/s, of the capacitance changes in air capacitors due to moisture in the atmosphere. It is shown that these changes may be considerably in excess of those due to the alterations in the permittivity of the air. Over the range of relative humidity 30¿65% the total change in capacitance can be about 3 parts in 10 000 at room temperatures. The full advantage of the otherwise high stability of a precision air capacitor is lost when this effect is ignored.
Keywords
capacitance measurement; capacitors;
fLanguage
English
Journal_Title
Electrical Engineers - Part II: Power Engineering, Journal of the Institution of
Publisher
iet
Type
jour
DOI
10.1049/ji-2.1948.0199