DocumentCode
1519198
Title
Interlaboratory comparison of high direct voltage resistor dividers
Author
Li, Yi ; Rungis, Juris ; Kim, Kyu-Tae ; Cho, Yong Myung ; McComb, Terry R. ; Dunn, John G. ; Van der Zwan, Len ; Hoffman, D.
Author_Institution
High Voltage Lab., CSIRO, Lindfield, NSW, Australia
Volume
48
Issue
2
fYear
1999
fDate
4/1/1999 12:00:00 AM
Firstpage
158
Lastpage
161
Abstract
A 150-kV divider from the National Measurements Laboratory of Australia was used as a travelling standard in comparison tests against standard dividers maintained at the Korean Research Institute of Standards and Science and the National Research Council of Canada. Results are presented in terms of the relative ratio changes between these dividers and the transfer standard under high voltages. In addition to establishing the relative agreement in high direct voltage measurements, the comparison tests were shown to be especially valuable for evaluating the ratio drifts of the dividers under prolonged application of high voltage
Keywords
high-voltage techniques; transfer standards; voltage dividers; voltage measurement; 150 kV; high direct voltage measurement; interlaboratory comparison; ratio drift; resistor divider; transfer standard; travelling standard; Australia; Corona; Councils; Electrical resistance measurement; Laboratories; Measurement standards; Resistors; Temperature; Testing; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.769552
Filename
769552
Link To Document