DocumentCode :
1520612
Title :
A method of calibrating a field-strength measuring set
Author :
Colebrook, F.M. ; Gordon-Smith, A.C.
Volume :
88
Issue :
1
fYear :
1941
fDate :
3/1/1941 12:00:00 AM
Firstpage :
15
Lastpage :
17
Abstract :
It is shown that a field-strength measuring set having a symmetrical closed-loop aerial coupled inductively through an electric screen to an unsymmetrical amplifier, can conveniently be calibrated in terms of a measured current passed through the coupling coil. The calibration so determined was found to be in satisfactory agreement with standard-field calibrations at wavelengths of 8 m. and 20 m.
Keywords :
antennas;
fLanguage :
English
Journal_Title :
Electrical Engineers - Part III: Communication Engineering, including the Proceedings of the Wireless Section of the Institution, Journal of the Institution of
Publisher :
iet
Type :
jour
DOI :
10.1049/ji-3-1.1941.0004