Abstract
Novel indicators based on distance measures are developed and compared to quantify changes in electroencephalogram signal resulting from hypoxic-asphyxic injury. An injury index is derived based on the measures. The Itakura distance-based index is found to have the highest correlation with the long-term outcome as measured by the neurological deficit scores.
Keywords
electroencephalography; medical signal processing; EEG analysis; Itakura distance-based index; distance measures; electrodiagnostics; hypoxic-asphyxic injury; injury-related EEG signal changes quantification; long-term outcome; neurological deficit scores; piglets; Animals; Asphyxia; Blood; Brain injuries; Brain modeling; Electroencephalography; Low pass filters; Monitoring; Power system modeling; Real time systems; Animals; Electroencephalography; Ischemic Attack, Transient; Linear Models; Models, Neurological; Monitoring, Physiologic; Signal Processing, Computer-Assisted; Swine;