• DocumentCode
    1523158
  • Title

    RADC cathode life test program

  • Author

    Bussey, D. ; Daniszewski, E. ; Novak, M. ; Ryan, J. ; Wilkinson, J.

  • Author_Institution
    Rome Air Dev. Center, Griffiss AFB, NY, USA
  • Volume
    37
  • Issue
    12
  • fYear
    1990
  • fDate
    12/1/1990 12:00:00 AM
  • Firstpage
    2612
  • Lastpage
    2613
  • Abstract
    This brief is an update of the RADC cathode life test program and includes details of evaluation procedures, progress, and future plans. A technique has been developed which permits repeatable temperature measurements on cathode test vehicles using a two-color pyrometer. The setup of the pyrometer for the cathode activity plot measurements is critical. The technique developed, when compared to the previously used measurement procedures, has several advantages: (1) an increase in the repeatability of the measurement data; (2) decreased instrumentation setup time; (3) adjustments eliminating any jarring or jolting of the instrumentation during setup positioning; and (4) different individuals can perform the measurements and obtain similar results
  • Keywords
    cathodes; life testing; pyrometers; temperature measurement; thermionic cathodes; RADC cathode life test program; cathode activity plot; cathode test vehicles; evaluation procedures; temperature measurements; thermionic emitters; two-color pyrometer; Cathodes; Contracts; Knee; Life testing; NASA; Position measurement; Temperature; Time measurement; Vehicles; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/16.64540
  • Filename
    64540