DocumentCode
1524463
Title
Comparison Between NPL and NMIJ of Diameter and Scattering Parameter Measurements of Precision 1.85 mm Coaxial Air Lines
Author
Horibe, Masahiro ; Ridler, Nick M.
Author_Institution
Nat. Metrol. Inst. of Japan, Nat. Inst. of Adv. Ind. Sci. & Technol., Tsukuba, Japan
Volume
60
Issue
7
fYear
2011
fDate
7/1/2011 12:00:00 AM
Firstpage
2327
Lastpage
2334
Abstract
This paper summaries a bilateral comparison of dimensional measurements of the diameters of two precision 1.85-mm coaxial air lines and associated electrical scattering parameter measurements. The measurements were independently made by two national metrology institutes: the National Metrology Institute of Japan and the National Physical Laboratory. The laboratories also calculated the characteristic impedances and their uncertainties based on the measured diameter values and uncertainties. The difference between the characteristic impedances calculated by the two laboratories for the two lines was less than 0.2 Ω. The uncertainty of this difference at a 95% level of confidence was 0.3 Ω. The scattering parameter measurement results agreed well at almost all comparison frequencies from 5 to 65 GHz.
Keywords
S-parameters; coaxial cables; electric impedance measurement; dimensional measurements; frequency 5 GHz to 65 GHz; precision coaxial air lines; scattering parameter measurements; Conductors; Frequency measurement; Measurement uncertainty; Scattering parameters; Standards; Transmission line measurements; Uncertainty; Characteristic impedance; measurement comparison; precision 1.85-mm coaxial air lines; scattering parameter;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2011.2135510
Filename
5772929
Link To Document