Dc voltage sensorless control method for three-phase grid-connected inverters
Author :
Wang, Zhen ; Chang, Ly-Yu ; Mao, Min
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of New Brunswick, Fredericton, NB, Canada
Volume :
3
Issue :
4
fYear :
2010
fDate :
7/1/2010 12:00:00 AM
Firstpage :
552
Lastpage :
558
Abstract :
A novel dc-link voltage sensorless technique for a three-phase grid-connected inverter is presented. Based on predictive and real-time sampling schemes, the required pulse width modulation (PWM) output voltage vector is accurately predicted by measuring the grid voltage and the inverter output current. A q-axis current proportional-integral (PI) controller is also used. The controller forces the output current to accurately follow its reference, and is also used to derive the dc-link voltage. By using this method, the dc-link voltage is not obtained from a voltage sensor, but instead is obtained from inverter output current information. Test results show that the output current of the resultant inverter is of high quality at steady state and can follow its reference quickly in dynamic states as well.
Keywords :
PI control; PWM invertors; sensors; Dc voltage sensorless control method; PI control; dc-link voltage; predictive schemes; pulse width modulation output voltage vector; q-axis current proportional-integral controller; real-time sampling schemes; three-phase grid-connected inverters; voltage sensor;
fLanguage :
English
Journal_Title :
Power Electronics, IET
Publisher :
iet
ISSN :
1755-4535
Type :
jour
DOI :
10.1049/iet-pel.2008.0282
Filename :
5497962
Link To Document :
بازگشت