Title :
New findings in the occurrence of false-healing in plastic encapsulated microcircuits using scanning acoustic microscopy
Author :
Ranade, Yogendra ; Pecht, Michael G. ; Moore, Thomas M.
Author_Institution :
LSI Logic Corp., Milpitas, CA, USA
fDate :
6/1/1999 12:00:00 AM
Abstract :
“False-healing” refers to the occasionally observed reduction of delamination in plastic encapsulated microcircuits, In previous studies, “false-healing” was reported only at the leadframe-plastic interface. It was thought that the chemical contaminants present in the flux enter the package and form corrosive products which fill up the internal air gaps. This paper reports on some new findings in the occurrence of false-healing in plastic packages using scanning acoustic microscopy. This study found that false-healing also occurs in instances where there was no exposure to corrosive media. Additionally, false healing was observed at the die-plastic interface, where chemical contaminants could not reach. Alternate explanations for this phenomenon are suggested and its impact on damage assessment of plastic encapsulated microcircuits is discussed
Keywords :
acoustic microscopy; delamination; encapsulation; failure analysis; integrated circuit packaging; integrated circuit testing; plastic packaging; soldering; air gap; chemical contaminant; corrosion; delamination; die-plastic interface; failure analysis; false healing; leadframe-plastic interface; plastic encapsulated microcircuit; plastic package; scanning acoustic microscopy; solder flux; Assembly; Chemicals; Delamination; Electronic packaging thermal management; Integrated circuit packaging; Lead; Microscopy; Plastic packaging; Temperature; Thermal stresses;
Journal_Title :
Components and Packaging Technologies, IEEE Transactions on
DOI :
10.1109/6144.774743