• DocumentCode
    1528635
  • Title

    Integrated Modeling and Enhanced Control of DFIG Under Unbalanced and Distorted Grid Voltage Conditions

  • Author

    Xu, Hailiang ; Hu, Jiabing ; He, Yikang

  • Author_Institution
    Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China
  • Volume
    27
  • Issue
    3
  • fYear
    2012
  • Firstpage
    725
  • Lastpage
    736
  • Abstract
    This paper focuses on the enhanced control and improved fault-ride-through capability of a doubly fed induction generator (DFIG)-based wind turbine system under both unbalanced and distorted grid voltage conditions. A more integrated mathematical model of DFIG is first set up with both the negative-sequence and the low-order harmonic grid voltages considered. Based on the developed model, the instantaneous active/reactive powers and electromagnetic toque are redefined in detail. Besides, four alternative control targets and their corresponding rotor current references are calculated and assigned. A novel current controller, consisting of a conventional PI regulator and a dual-frequency resonant (DFR) compensator, tuned at twice and six times the grid frequency, named PI-DFR controller, is designed to regulate the fundamental and the fifth- and seventh-order harmonic components simultaneously. Experiment studies verify the correctness of the developed model and the effectiveness of the suggested control strategies in improving the fault-ride-through capability of a DFIG system under such adverse grid conditions.
  • Keywords
    PI control; asynchronous generators; control system synthesis; electric current control; frequency control; machine control; mathematical analysis; power generation control; power generation faults; power grids; power system harmonics; reactive power; wind turbines; DFIG; DFR compensator; PI regulator; PI-DFR controller design; current controller; distorted grid voltage condition; doubly fed induction generator; dual-frequency resonant compensator; electromagnetic toque; fifth-order harmonic component; grid frequency; improved fault-ride-through capability; instantaneous active-reactive power; integrated mathematical model; low-order harmonic grid voltage; negative-sequence; rotor current reference calculation; seventh-order harmonic component; unbalanced grid voltage condition; wind turbine system; Electromagnetics; Harmonic analysis; Rotors; Stators; Vectors; Voltage control; Wind turbines; Control; doubly fed induction generator (DFIG); modeling; unbalanced and distorted grid voltage conditions; wind power;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2012.2199495
  • Filename
    6209410