DocumentCode
1528813
Title
Effect of anode and insulator materials on plasma focus sheath (pinch) current
Author
Shyam, A. ; Rout, R.K.
Author_Institution
Div. of Neutron Phys., Bhabha Atomic Res. Centre, Mumbai
Volume
25
Issue
5
fYear
1997
fDate
10/1/1997 12:00:00 AM
Firstpage
1166
Lastpage
1168
Abstract
Plasma sheath (pinch) current in a low energy (2.2 kJ) plasma focus device was measured fur different anode and insulator materials. Among the anode materials, the highest sheath current was observed with tungsten and the lowest with aluminum. Among the ceramic insulators the maximum plasma sheath current was obtained with quartz and the minimum with alumina. The computed high Z (atomic number) impurities in plasma sheath, however, were least in the plasma focus with alumina insulator. None of the nonceramic (plastic) insulators produced neutrons, as the plasma sheath was nonuniform and was highly contaminated with impurities
Keywords
alumina; aluminium; anodes; ceramic insulators; pinch effect; plasma focus; plasma sheaths; quartz; tungsten; 2.2 kJ; Al; Al2O3; W; alumina; aluminum; anode material; ceramic insulators; impurities; insulator material; pinch current; plasma focus device; plasma focus sheath; plasma sheath current; plastic insulators; quartz; tungsten; Anodes; Current measurement; Energy measurement; Impurities; Insulation; Plasma devices; Plasma materials processing; Plasma measurements; Plasma sheaths; Pollution measurement;
fLanguage
English
Journal_Title
Plasma Science, IEEE Transactions on
Publisher
ieee
ISSN
0093-3813
Type
jour
DOI
10.1109/27.649641
Filename
649641
Link To Document