• DocumentCode
    1530879
  • Title

    Ionizing radiation dosimetry and noise in small geometry devices

  • Author

    Vickers, V.E. ; Shepherd, F.D. ; Burke, E.A.

  • Author_Institution
    Air Force Cambridge Research Laboratories Air Force Systems Command Bedford, Massachusetts
  • Volume
    21
  • Issue
    6
  • fYear
    1974
  • Firstpage
    107
  • Lastpage
    112
  • Abstract
    A code is presented to predict the statistics of transient responses to gamma radiation of rectangular solid state devices. Use of the chordlength distribution and assuming the radiation flux isotropic obviates use of Monte Carlo techniques, so that the code runs fast enough for exploratory use. It is discovered that, for small detectors, relatively large-area non-square thin detectors are advantageous.
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1974.6498913
  • Filename
    6498913