  • Abstract
    A high rate neutron counting is achieved while minimizing the dead-time of the counting chain. The paper shows that too short a shaping time constant gives rise to double pulses at the output of the discriminator for a single neutron. Therefore, the shaping time must be optimized in order to minimize the dead-time while also avoiding counting errors. Simulations and experimental results for a 3He chain at different shaping time constants are presented and discussed
  • Keywords
    helium-3 counters; neutron detection; nuclear electronics; pulse shaping circuits; 3He tubes; He; counting chain; counting errors; dead-time; double pulses; high rate neutron counting; shaping time constant; signal shaping optimization; Anodes; Detectors; Electrons; Helium; Ionization; Neutrons; Protons; Pulse amplifiers; Signal generators; Wire;