• DocumentCode
    1531283
  • Title

    Performance of a prototype CMS hadron barrel calorimeter in a test beam

  • Author

    Bodek, Arie

  • Author_Institution
    Dept. of Phys. & Astron., Rochester Univ., NY, USA
  • Volume
    46
  • Issue
    3
  • fYear
    1999
  • fDate
    6/1/1999 12:00:00 AM
  • Firstpage
    407
  • Lastpage
    409
  • Abstract
    We report on the performance of a prototype CMS Hadron Barrel Calorimeter (HCAL) module in a test beam. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. Placing a lead tungstate crystal electromagnetic calorimeter in front of HCAL affects the linearity and energy resolution of the combined system to hadrons. The data are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation
  • Keywords
    electron detection; meson detection; position sensitive particle detectors; solid scintillation detectors; Cu; PbWO4; copper absorber plates; energy resolution; lead tungstate crystal electromagnetic calorimeter; longitudinal readout segmentation; prototype CMS hadron barrel calorimeter; prototype sampling calorimeter; sampling frequency; scintillator tiles; total absorber depth; wavelength shifting fibers; Collision mitigation; Copper; Electrons; Energy resolution; Linearity; Mesons; Prototypes; Sampling methods; Testing; Tiles;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.775552
  • Filename
    775552