DocumentCode
1534065
Title
Sliding transformers for linear contactless power delivery
Author
Barnard, Jacobus M. ; Ferreira, Jan A. ; Van Wyk, Jacobus Daniel
Author_Institution
Energy Lab., Rand Afrikaans Univ., Johannesburg, South Africa
Volume
44
Issue
6
fYear
1997
fDate
12/1/1997 12:00:00 AM
Firstpage
774
Lastpage
779
Abstract
Contactless power delivery systems for mobile loads use transformers comprised of a core with a secondary winding sliding along an extended primary winding. The sliding transformer is identified as the most limiting component in the system and is analyzed by representing it as a special, multiturn power transmission line. Two performance parameters, namely the transmission line efficiency and system penalty factor, are introduced. It is shown that fundamental restrictions may limit the attainable performance of the system. The inductance of the primary winding is identified as a parameter which can be optimized to improve the system performance. Experimental results for a short- and a long-stroke transformer are presented
Keywords
electromagnetic induction; power supplies to apparatus; power transformer testing; transformer cores; transformer windings; linear contactless power delivery; long-stroke transformer; magnetic cores; multiturn power transmission line; performance parameters; primary winding; secondary winding; short-stroke transformer; sliding transformers; system penalty factor; transmission line efficiency; Capacitance; Capacitors; Conductors; Inductance; Inverters; Jacobian matrices; Magnetic cores; Power transmission lines; Rectifiers; Transformer cores;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/41.649938