DocumentCode
153511
Title
Modification of the X-ray diagnostics of electron energy distributions in gyrotrons
Author
Arkhipov, Alexander ; Dvoretskaya, Natalya ; Gantenbein, Gerd ; Louksha, Oleg ; Samartsev, Andrey ; Sominski, Gennadi
Author_Institution
St. Petersburg State Polytech. Univ., St. Petersburg, Russia
fYear
2014
fDate
14-19 Sept. 2014
Firstpage
1
Lastpage
2
Abstract
Scattered x-rays were utilized for determination of the electron energy distributions at a gyrotron collector. Performed calculations and experiments demonstrated that scattering in the diagnostic window has only minor effect on the radiation spectra in the gyrotron-relevant conditions. The primary advantage of the proposed diagnostic scheme consists in reduction of the density of treated x-rays flux down to the optimal level for spectrometers of the energy-dispersive type. The experimental configuration for full-beam-averaged data acquisition has been practically tested. A modification of the setup is discussed aimed to obtain information with an optimal spatial resolution.
Keywords
X-ray scattering; data acquisition; gyrotrons; spectrometers; X-ray diagnostics; diagnostic window; electron energy distributions; energy-dispersive type; full-beam-averaged data acquisition; gyrotron collector; radiation spectra; scattered X-rays; spectrometers; treated X-rays flux; Collimators; Electron beams; Gyrotrons; Layout; Photonics; Radio frequency; Scattering;
fLanguage
English
Publisher
ieee
Conference_Titel
Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2014 39th International Conference on
Conference_Location
Tucson, AZ
Type
conf
DOI
10.1109/IRMMW-THz.2014.6956507
Filename
6956507
Link To Document