Title :
An Optimization-Based Study of Equivalent Circuit Models for Representing Recordings at the Neuron–Electrode Interface
Author :
Thakore, Vaibhav ; Molnar, Peter ; Hickman, James J.
Author_Institution :
Dept. of Phys., Univ. of Central Florida, Orlando, FL, USA
Abstract :
Extracellular neuroelectronic interfacing is an emerging field with important applications in the fields of neural prosthetics, biological computation, and biosensors. Traditionally, neuron-electrode interfaces have been modeled as linear point or area contact equivalent circuits but it is now being increasingly realized that such models cannot explain the shapes and magnitudes of the observed extracellular signals. Here, results were compared and contrasted from an unprecedented optimization-based study of the point contact models for an extracellular “on-cell” neuron-patch electrode and a planar neuron-microelectrode interface. Concurrent electrophysiological recordings from a single neuron simultaneously interfaced to three distinct electrodes (intracellular, “on-cell” patch, and planar microelectrode) allowed novel insights into the mechanism of signal transduction at the neuron-electrode interface. After a systematic isolation of the nonlinear neuronal contribution to the extracellular signal, a consistent underestimation of the simulated suprathreshold extracellular signals compared to the experimentally recorded signals was observed. This conclusively demonstrated that the dynamics of the interfacial medium contribute nonlinearly to the process of signal transduction at the neuron-electrode interface. Further, an examination of the optimized model parameters for the experimental extracellular recordings from sub- and suprathreshold stimulations of the neuron-electrode junctions revealed that ionic transport at the “on-cell” neuron-patch electrode is dominated by diffusion whereas at the neuron-microelectrode interface the electric double layer (EDL) effects dominate. Based on this study, the limitations of the equivalent circuit models in their failure to account for the nonlinear EDL and ionic electrodiffusion effects occurring during signal transduction at the neuron-electrode interfaces are discussed.
Keywords :
biomedical electrodes; biomedical electronics; equivalent circuits; interface phenomena; medical signal processing; microelectrodes; neurophysiology; optimisation; recording; biological computation; biosensors; electric double layer effects; electrophysiological recordings; equivalent circuit models; equivalent circuits; experimental extracellular recordings; extracellular “on-cell” neuron-patch electrode; extracellular neuroelectronic interfacing; interfacial medium; ionic electrodiffusion effects; ionic transport; neural prosthetics; neuron-electrode interface recordings; neuron-electrode interfaces; neuron-electrode junctions; optimization-based study; planar neuron-microelectrode interface; point contact models; signal transduction; simulated suprathreshold extracellular signals; Equivalent circuits; Extracellular; Integrated circuit modeling; Mathematical model; Microelectrodes; Neurons; Microelectrode arrays (MEAs); neuroelectronic interface; nonlinear ionic electrodiffusion; whole-cell biosensors; Animals; Cell Line; Electrophysiological Phenomena; Equipment Design; Extracellular Space; Mice; Microelectrodes; Models, Neurological; Neurons; Patch-Clamp Techniques; Rats;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2012.2203820