    Variation of Respiratory Resistance Suggests Optimization of Airway Caliber

  • Author

    Johnson, Arthur T. ; Jones, Samantha C. ; Pan, James J. ; Vossoughi, Jafar

  • Author_Institution
    Fischell Dept. of Bioeng., Univ. of Maryland, College Park, MD, USA
  • Volume
    59
  • Issue
    8
  • fYear
    2012
  • Firstpage
    2355
  • Lastpage
    2361
  • Abstract
    Physiologically optimized processes, such as respiration, walking, and cardiac function, usually show a range of variability about the optimized value. Airway resistance has, in the past, been noted as variable, and this variability has been connected to pulmonary disease (e.g., asthma). A hypothesis was presented many years ago that postulated airway resistance as an optimized parameter in healthy individuals, and we have noticed that respiratory measurements made with the airflow perturbation device (APD) tend to be variable in nature. It was posited that this variability indicates that respiratory resistance is optimized similarly to other physiological processes. Fifty subjects with a wide range of demographics volunteered to have 100 measurements made of their respiratory resistances. Resistances were separated into inhalation and exhalation phases. These were plotted and shown to have frequency distributions that were consistent with expectations for an optimized process. The frequency distributions were not quite symmetrical, being skewed slightly toward upper resistances. Comparison between subject data and data from a mechanical respiratory analog showed that subject resistance variation is overwhelmingly from the respiratory system and not from the APD.
  • Keywords
    biomedical equipment; biomedical measurement; cardiology; diseases; gait analysis; pneumodynamics; airflow perturbation device; airway caliber; cardiac function; exhalation phases; mechanical respiratory; optimization; optimized processing; physiological processing; physiologically optimized processing; postulated airway resistance; pulmonary disease; respiratory measurements; respiratory resistances; subject resistance variation; walking; Correlation; Electrical resistance measurement; Humans; Immune system; Resistance; Standards; Testing; Airflow perturbation device; asthma; respiration; Adolescent; Adult; Airway Resistance; Asthma; Equipment Design; Female; Humans; Male; Middle Aged; Respiratory Function Tests; Respiratory Mechanics;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2012.2204055
  • Filename
    6215025