• DocumentCode
    1537131
  • Title

    Monitoring off-line and on-line PD under impulsive voltage on induction motors - part 1: standard procedure

  • Author

    Tozzi, M. ; Cavallini, A. ; Montanari, G.C.

  • Author_Institution
    Techimp Spa, Zola Predosa, Italy
  • Volume
    26
  • Issue
    4
  • fYear
    2010
  • Firstpage
    16
  • Lastpage
    26
  • Abstract
    This article is the first of a series of three that examines the correlation between off-line and on-line measurements on Type I random-wound motors. The off-line tests reported in this first article were carried out according to IEC 60034-18-4 to demonstrate that they are PD free under impulsive voltage conditions.
  • Keywords
    computerised monitoring; impulse testing; induction motor drives; insulation testing; machine insulation; machine testing; partial discharge measurement; voltage distribution; IEC 60034-18-4; adjustable speed drives; impulsive voltage; induction motors; interturn insulation; nonuniform voltage distribution; offline monitoring; online monitoring; overvoltages; partial discharge monitoring; partial discharges; premature motor failures; random-wound motors; IEC standards; Induction motors; Monitoring; Testing; Voltage; partial discharge, impulsive voltage, inverter-fed motor, PWM, ASD, random-wound motor, type test, qualification test, RPDIV, turn insulation;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0883-7554
  • Type

    jour

  • DOI
    10.1109/MEI.2010.5511185
  • Filename
    5511185