DocumentCode :
1540219
Title :
An approach to multibeam covariance matrices for adaptive beamforming in ultrasonography
Author :
Jensen, Are Charles ; Austeng, Andreas
Author_Institution :
Dept. of Inf., Univ. of Oslo, Oslo, Norway
Volume :
59
Issue :
6
fYear :
2012
fDate :
6/1/2012 12:00:00 AM
Firstpage :
1139
Lastpage :
1148
Abstract :
Medical ultrasound imaging systems are often based on transmitting, and recording the backscatter from, a series of focused broadband beams with overlapping coverage areas. When applying adaptive beamforming, a separate array covariance matrix for each image sample is usually formed. The data used to estimate any one of these covariance matrices is often limited to the recorded backscatter from a single transmitted beam, or that of some adjacent beams through additional focusing at reception. We propose to form, for each radial distance, a single covariance matrix covering all of the beams. The covariance matrix is estimated by combining the array samples after a sequenced time delay and phase shift. The time delay is identical to that performed in conventional delay-and-sum beamforming. The performance of the proposed approach in conjunction with the Capon beamformer is studied on both simulated data of scenes consisting of point targets and recorded ultrasound phantom data from a specially adapted commercial scanner. The results show that the proposed approach is more capable of resolving point targets and gives better defined cyst-like structures in speckle images compared with the conventional delay-and-sum approach. Furthermore, it shows both an increased robustness to noise and an increased ability to resolve point-like targets compared with the more traditional per-beam Capon beamformer.
Keywords :
array signal processing; biomedical ultrasonics; covariance matrices; medical signal processing; phantoms; white noise; adaptive beamforming; conventional delay-and-sum beamforming; cyst-like structures; medical ultrasound imaging systems; multibeam covariance matrices; point-like targets; single array covariance matrix; traditional per-beam Capon beamformer; ultrasonography; ultrasound phantom data; white noise properties; Array signal processing; Arrays; Covariance matrix; Delay effects; Imaging; Noise; Vectors;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2012.2304