• DocumentCode
    1542154
  • Title

    3D-FRP: direct Fourier reconstruction with Fourier reprojection for fully 3-D PET

  • Author

    Matej, Samuel ; Lewitt, Robert M.

  • Author_Institution
    Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA, USA
  • Volume
    48
  • Issue
    4
  • fYear
    2001
  • fDate
    8/1/2001 12:00:00 AM
  • Firstpage
    1378
  • Lastpage
    1385
  • Abstract
    The direct Fourier method (DFM) for three-dimensional (3-D) reconstruction of a 3-D volume is based on the relationship between the 3-D Fourier transform (FT) of the volume and the two-dimensional (2-D) FT of a parallel-ray projection of the volume. The direct Fourier method has the potential for very fast reconstruction, but a straightforward implementation of the method leads to unsatisfactory results. This paper presents an implementation of the direct Fourier method for fully 3-D positron emission tomography (PET) data with incomplete oblique projections (3D-FRP) that gives results as good as, or better than, those of a much slower 3-D filtered backprojection method (3DRP), and in the same time as a fast but less accurate method using Fourier rebinning (FORE) followed by slice-by-slice reconstruction. In common with 3DRP, 3D-FRP is based on a discretization of an inversion formula, so it is geometrically accurate for large oblique angles, and both methods involve reprojection of an initial image. The critical two steps in the 3D-FRP method are the estimations of the samples of the 3-D transform of the image from the samples of the 2-D transforms of the projections on the planes through the origin of Fourier space, and vice versa for reprojection. These steps use a gridding strategy, combined with new approaches for weighting in the transform and image domains. The authors´ experimental results confirm that good image accuracy can be achieved together with a short reconstruction time
  • Keywords
    Fourier transforms; image reconstruction; medical image processing; positron emission tomography; 3-D filtered backprojection method; 3D-FRP; Fourier reprojection; direct Fourier reconstruction; fully 3-D PET; image accuracy; incomplete oblique projections; inversion formula discretization; medical diagnostic imaging; nuclear medicine; parallel-ray projection; reconstruction time; reprojection; very fast reconstruction; volume image reconstruction; Approximation error; Biomedical image processing; Design for manufacture; Fourier transforms; Image quality; Image reconstruction; Positron emission tomography; Radiology; Single photon emission computed tomography; Two dimensional displays;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.958359
  • Filename
    958359