Title :
Development of a phoswich detector for a continuous blood-sampling system
Author :
Yamamoto, S. ; Tarutani, K. ; Suga, M. ; Minato, K. ; Watabe, H. ; Iida, H.
Author_Institution :
Kobe City Coll. of Technol., Japan
Volume :
48
Issue :
4
fYear :
2001
fDate :
8/1/2001 12:00:00 AM
Firstpage :
1408
Lastpage :
1411
Abstract :
The authors have developed a phoswich detector composed of a plastic scintillator and a BGO scintillator for a continuous blood-sampling system. The beta particle (positron) from the tube is detected by the plastic scintillator and emits 511-keV gamma photons. The BGO scintillator that is optically coupled to the plastic scintillator detects one of the gamma photons. Since the decay time of the plastic scintillator and the BGO are very different, it is possible to discriminate true (beta+gamma) events from background gamma events. First, the pulse height and pulse shape of plastic scintillator for beta particles and EGO scintillator for 511-keV gamma photons were measured and compared to estimate the possibility of the proposed method. Second, the proposed phoswich detector was fabricated and tested. Absolute sensitivity for Ga-68 (maximum energy of 1.90 MeV) and F-18 (maximum energy of 633 keV) positrons was measured and compared with conventional beta detector of similar size. The absolute sensitivity of the developed detector was 0.15 counts/Bq for Ga-68 positrons at the center of the detector. This was approximately five times higher in sensitivity than the conventional beta detector. The absolute sensitivity of the developed detector for F-18 positrons was 0.017 counts/Bq. The count rate of the developed detector was linear up to 10 kcps. The background count rate was small. These results indicate that the developed detector is useful not only for higher energy positrons such as O-15 but also for lower energy positrons such as F-18 or C-11
Keywords :
beta-ray detection; biomedical equipment; blood; gamma-ray detection; positron emission tomography; solid scintillation detectors; 1.9 MeV; 511 keV; 633 keV; BGO scintillator; C; C-11; F; F-18; Ga; O; O-15; PET; continuous blood-sampling system; medical instrumentation; phoswich detector development; plastic scintillator; pulse height; pulse shape; Beta rays; Gamma ray detection; Gamma ray detectors; Optical pulse shaping; Optical sensors; Plastics; Positrons; Pulse measurements; Shape measurement; Stimulated emission;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.958367
Filename :
958367
Link To Document :
بازگشت