• DocumentCode
    1542358
  • Title

    3-D reconstruction in PET cameras with irregular sampling and depth of interaction

  • Author

    Virador, P.R.G. ; Moses, W.W. ; Huesman, R.H. ; Qi, J.

  • Author_Institution
    Lawrence Berkeley Lab., CA, USA
  • Volume
    48
  • Issue
    4
  • fYear
    2001
  • fDate
    8/1/2001 12:00:00 AM
  • Firstpage
    1524
  • Lastpage
    1529
  • Abstract
    Presents three-dimensional (3-D) reconstruction algorithms that address fully 3-D tomographic reconstruction for a septa-less, stationary, and rectangular camera. The field of view (FOV) encompasses the entire volume enclosed by detector modules capable of measuring depth of interaction (DOI). The filtered backprojection-based algorithms incorporate DOI, accommodate irregular sampling, and minimize interpolation in the data by defining lines of response between the measured interaction points. The authors use fixed-width, evenly spaced radial bins in order to use the fast Fourier transform but use irregular angular sampling to minimize the number of unnormalizable zero efficiency sinogram bins. To address persisting low-efficiency bins, the authors perform two-dimensional (2-D) nearest neighbor radial smoothing, employ a semi-iterative procedure to estimate the unsampled data, and mash the “in plane” and the first oblique projections to reconstruct the 2-D image in the 3DRP algorithm. The authors present artifact-free, essentially spatially isotropic images of Monte Carlo data with full-width at half-maximum resolutions of 1.5, 2.3, and 3.1 mm at the center, in the bulk, and in the corners of the FOV, respectively
  • Keywords
    Monte Carlo methods; biomedical equipment; cameras; fast Fourier transforms; image reconstruction; medical image processing; positron emission tomography; 2-D nearest neighbor radial smoothing; 3-D reconstruction; Monte Carlo data; PET cameras; artifact-free essentially spatially isotropic images; data interpolation minimization; fixed-width evenly spaced radial bins; interaction depth; irregular sampling; medical diagnostic imaging; medical instrumentation; nuclear medicine; oblique projections; semiiterative procedure; unsampled data; Cameras; Detectors; Image reconstruction; Interpolation; Positron emission tomography; Reconstruction algorithms; Sampling methods; Three dimensional displays; Two dimensional displays; Volume measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.958391
  • Filename