DocumentCode
1542986
Title
Stator resistance voltage-drop compensation for open-loop AC drives
Author
Francis, C.J. ; De La Parra, H. Zelaya
Author_Institution
Sch. of Electron. & Electr. Eng., Birmingham Univ., UK
Volume
144
Issue
1
fYear
1997
fDate
1/1/1997 12:00:00 AM
Firstpage
21
Lastpage
26
Abstract
The paper presents two simple stator resistance voltage-drop compensation methods that maintain the stator flux linkage constant in the steady state and achieve approximately constant flux linkage during transient conditions. These methods are based on an induction motor model in a rotating reference frame. A mathematical analysis of the two possible alternatives is shown, indicating the stability limits for each. Practical results are then compared with the traditional volts/hertz (V/f) configuration and the stability limits verified
Keywords
AC motor drives; compensation; machine theory; stability; stators; induction motor model; mathematical analysis; open-loop AC motor drives; rotating reference frame; stability limits; stator flux linkage; stator resistance voltage-drop compensation; steady-state operation; volts/hertz configuration;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:19970579
Filename
583364