• DocumentCode
    1543139
  • Title

    Using on line insulation testing to implement generator predictive maintenance

  • Author

    Warren, V.

  • Author_Institution
    8247 North Lick Creek Rd., Lyles, TN, USA
  • Volume
    13
  • Issue
    2
  • fYear
    1997
  • Firstpage
    17
  • Lastpage
    21
  • Abstract
    Aspects of preventive and predictive maintenance for a hydrogenerator stator winding insulation system are discussed in this article. A specific case study on a 31 MVA hydrogenerator is presented. The new method had to provide the staff with a precise and timely assessment of the state of the insulation without prolonged outages and substantial manpower allocations.
  • Keywords
    hydroelectric generators; insulation testing; machine insulation; machine testing; maintenance engineering; stators; 31 MVA; hydrogenerator stator winding; on line insulation testing; predictive maintenance; preventive maintenance; Aging; Capacitance; Condition monitoring; Dielectrics and electrical insulation; Inspection; Insulation testing; Manufacturing; Predictive maintenance; Preventive maintenance; Stator windings;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0883-7554
  • Type

    jour

  • DOI
    10.1109/57.583422
  • Filename
    583422