DocumentCode
1543839
Title
Robust pole-placement algorithm for adaptive control
Author
Berger, C.S.
Author_Institution
Dept. of Electr. Eng., Monash Univ., Melbourne, Clayton, Vic., Australia
Volume
135
Issue
6
fYear
1988
fDate
11/1/1988 12:00:00 AM
Firstpage
493
Lastpage
498
Abstract
Pole-placement algorithms can be ill conditioned, if the desired closed-loop poles are not appropriately chosen with respect to the open-loop poles. The algorithm used in the paper automatically adjusts the closed-loop poles (within defined limits), to ensure a well conditioned design equation. This facility is particularly useful with adaptive controllers which do not evaluate open-loop poles.
Keywords
adaptive control; closed loop systems; poles and zeros; stability; adaptive control; closed loop systems; closed-loop poles; robust pole placement; well conditioned design equation;