Title :
A three photon noise SIS heterodyne receiver at submillimeter wavelength
Author :
Karpov, A. ; Blondel, J. ; Voss, M. ; Gundlach, K.-H.
Author_Institution :
Inst. de Radioastron. Millimetrique, St. Martin d´Heres, France
fDate :
6/1/1999 12:00:00 AM
Abstract :
An ultra-low noise single sideband SIS receiver has been prepared for radio astronomy at the sub millimeter wavelength /spl lambda//spl ap/0.85 mm. The minimum single sideband receiver noise temperature of 48 K corresponds to 3 h/spl omega//k or equivalent number of 3 photon of noise. The minimum single sideband SIS mixer noise temperature is about 20 K, close to 1.2 h/spl omega//k, or one photon of noise. The Nb/AlOx/Nb junctions with a Josephson critical current density of 9 KA/cm/sup 2/ and with the area of about 0.9 /spl mu/m/sup 2/ were used. The receiver has been tested at the 30 meter IRAM radio telescope in the winter seasons of 1997 and 1998. The observations at the radio telescope are speeded up by a factor of two to three with the new receiver.
Keywords :
aluminium compounds; heterodyne detection; niobium; submillimetre astronomy; submillimetre wave receivers; superconducting device noise; superconductor-insulator-superconductor mixers; 0.85 mm; IRAM radiotelescope; Nb-AlO-Nb; Nb/AlOx/Nb Josephson junction; SIS mixer; critical current density; noise temperature; radioastronomy; single sideband SIS receiver; submillimeter wave heterodyne receiver; Josephson junctions; Niobium; Noise figure; Noise measurement; Optical receivers; Radio astronomy; Superconducting device noise; Superconducting devices; Telescopes; Temperature;
Journal_Title :
Applied Superconductivity, IEEE Transactions on