DocumentCode :
1544397
Title :
Single event upset tests of an 80-Mb/s optical receiver
Author :
Faccio, F. ; Berger, G. ; Gill, K. ; Huhtinen, M. ; Marchioro, A. ; Moreira, P. ; Vasey, F.
Author_Institution :
EP Div., CERN, Geneva, Switzerland
Volume :
48
Issue :
5
fYear :
2001
fDate :
10/1/2001 12:00:00 AM
Firstpage :
1700
Lastpage :
1707
Abstract :
This paper studies the single event upset (SEU) sensitivity of a radiation-tolerant 80-Mb/s receiver developed for the CMS Tracker digital optical link. Bit error rate (BER) measurements were made while irradiating the receiver with protons and neutrons at different beam energies and incident angles and for a wide range of optical power levels in the link. Monte Carlo simulations have also been used to assist in the interpretation of the experimental results. As expected, the photodiode is the most sensitive element to SEU. The fake signal induced by direct ionization dominates the bit-error cross-section only for protons incident on the photodiode at large angles and low levels of optical power. Comparison of the neutron and proton bit-error cross-sections demonstrates that nuclear interactions contribute significantly to the proton-induced SEU errors and that they will dominate the radiation-induced error rate in the real Tracker application
Keywords :
Monte Carlo methods; optical links; optical receivers; photodiodes; position sensitive particle detectors; CMS Tracker digital optical link; Monte Carlo simulations; direct ionization; optical receiver; photodiode; radiation-tolerant receiver; single event upset; Bit error rate; Collision mitigation; Neutrons; Optical fiber communication; Optical receivers; Optical sensors; Photodiodes; Protons; Single event upset; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.960360
Filename :
960360
Link To Document :
بازگشت