  • Abstract
    In lightning investigations we need simple yet reasonably accurate expressions for the horizontal electric field for an imperfectly conducting ground plant. The Cooray-Rubenstein (see Radio Sci., vol.27, no.4, p.529-38, 1992, and IEEE Trans. Electromag. Compat., vol.38, no.8, p.531-535, 1996) prediction model involves only the horizontal electric field expression for a perfectly conducting ground, the surface impedance, and the tangential magnetic field also for a perfectly conducting ground. We develop an exact version of this relationship and show analytically how and under what conditions it reduces to the CR expression
  • Keywords
    distribution networks; electric fields; electric impedance; electromagnetic induction; lightning; power cables; power transmission lines; Cooray-Rubenstein prediction model; EM coupling; horizontal electric field; imperfectly conducting ground plant; lightning; perfectly conducting ground; power lines; surface impedance; tangential magnetic field; Chromium; Electromagnetic coupling; Electromagnetic fields; Geometry; Lightning; Magnetic analysis; Magnetic fields; Optical coupling; Predictive models; Surface impedance;