• DocumentCode
    1545166
  • Title

    Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring

  • Author

    Kim, Kyeong-Hwa

  • Author_Institution
    Dept. of Electr. Eng., Seoul Nat. Univ. of Sci. & Technol., Seoul, South Korea
  • Volume
    58
  • Issue
    6
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    2565
  • Lastpage
    2568
  • Abstract
    To detect a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor, a simple online fault detecting scheme is presented. The proposed scheme is based on the monitoring of the second-order harmonic components in the q-axis current through harmonic analysis. To verify the effectiveness of the proposed scheme, a test motor which allows an interturn short in the stator winding has been built, and the entire control system has been implemented using the DSP TMS320F28335.
  • Keywords
    digital control; fault diagnosis; machine control; permanent magnet motors; synchronous motors; DSP TMS320F28335; PMSM; control system; current harmonic monitoring; harmonic analysis; online fault detecting scheme; permanent magnet synchronous motor; q-axis current; second-order harmonic components; short-circuited turn; stator winding fault; test motor; Breakdown voltage; Control systems; Digital signal processing; Fault detection; Fault diagnosis; Harmonic analysis; Monitoring; Permanent magnet motors; Stator windings; Synchronous motors; Current harmonics; online fault diagnosis; permanent magnet synchronous motor (PMSM); stator turn fault;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2010.2060463
  • Filename
    5518423