DocumentCode :
1549193
Title :
New random inverter control technique for common mode voltage mitigation of motor drives
Author :
Lai, Y.S.
Author_Institution :
Dept. of Electr. Eng., Nat. Taipei Univ. of Technol., Taiwan
Volume :
146
Issue :
3
fYear :
1999
fDate :
5/1/1999 12:00:00 AM
Firstpage :
289
Lastpage :
296
Abstract :
The purpose of the paper is to present a new inverter control technique which not only mitigates the common mode voltage for motor drive applications but also significantly reduces the calculations required for high switching frequency control, in comparison with the conventional space vector modulation technique. Moreover, it is demonstrated that the presented technique improves the quality of inverter control by randomising the inverter switching frequency, thereby spreading the first dominant harmonic cluster which contributes to the noise. Experimental results derived from a microprocessor-based experimental drive system are presented to confirm the theoretical analysis
Keywords :
DC-AC power convertors; frequency control; harmonic distortion; invertors; machine control; machine testing; machine theory; motor drives; power conversion harmonics; applications; common mode voltage mitigation; first dominant harmonic cluster; high switching frequency control; inverter switching frequency randomisation; motor drives; random inverter control technique;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:19990108
Filename :
785331
Link To Document :
بازگشت