Title :
Lifetime evaluation of class E electrical insulation for small induction motors
Author_Institution :
Korea Electron. Technol. Inst., Seongnam, South Korea
Abstract :
Accelerated aging tests for induction motors with class E electrical insulation were conducted. The testing period exceeded one year and involved elevated temperatures, vibration, humidity, and voltage application. The activation energy of the aging process was estimated to be 0.72 ± 0.08 eV.
Keywords :
induction motors; life testing; machine insulation; machine testing; accelerated aging tests; activation energy; class E electrical insulation; lifetime evaluation; small induction motors; Coils; Consumer electronics; Gaussian distribution; Home appliances; Induction motors; accelerated life test; class E electrical insulation; induction motor; lifetime evaluation;
Journal_Title :
Electrical Insulation Magazine, IEEE
DOI :
10.1109/MEI.2011.5871364