DocumentCode :
1552896
Title :
Efficient ultrasonic synthetic aperture imaging
Author :
Karaman, M. ; Tavh, B.
Author_Institution :
Dept. of Electr. & Electron. Eng., Baskent Univ., Ankara, Turkey
Volume :
35
Issue :
16
fYear :
1999
fDate :
8/5/1999 12:00:00 AM
Firstpage :
1319
Lastpage :
1320
Abstract :
Synthetic aperture imaging employing a single active array channel in data acquisition, enables low cost systems to be realised, but produces poor image quality. An investigation is presented into a new synthetic aperture system which uses a single active transmit element and two active receive elements to carry out data acquisition. This approach improves the image quality by suppressing the grating and sidelobes, while preserving the simplicity of the front-end hardware
Keywords :
ultrasonic imaging; data acquisition; ultrasonic synthetic aperture imaging;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19990909