DocumentCode :
1553298
Title :
Experimental and Theoretical Wall Temperatures of Hg HID Lamps
Author :
Zalach, J. ; Araoud, Z. ; Franke, St ; Charrada, K.
Author_Institution :
Leibniz Inst. for Plasma Sci. & Technol., INP Greifswald e.V., Greifswald, Germany
Volume :
39
Issue :
11
fYear :
2011
Firstpage :
2986
Lastpage :
2987
Abstract :
Thermography is an established experimental method to measure wall temperatures of high-pressure discharge lamps resulting in 2-D images. However, theoretical models, including the heat balance of the tube wall, are usually based on a cylinder symmetric 2-D model, where the tube wall surface is represented by a 1-D line. In this paper, a comparison between experimental and theoretical results are presented, where a 2-D thermographic image is reconstructed from the model calculations. This allows visualizing and discussing of some capabilities and limitations of the theoretical model.
Keywords :
discharge lamps; tomography; 1D line; 2D thermographic image reconstruction; HID Lamps; cylinder symmetric 2D model; experimental wall temperatures; heat balance; high-intensity discharge lamps; high-pressure discharge lamps; theoretical wall temperatures; tube wall surface; Computational modeling; Discharges; Electrodes; High intensity discharge lamps; Plasma temperature; Temperature measurement; Arc discharge; lamps; warm up;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2011.2157364
Filename :
5875901
Link To Document :
بازگشت