• DocumentCode
    1554530
  • Title

    Millimetre-wave-imaging system at 95 GHz - quantitative performance evaluation

  • Author

    Zhang, Leiqi ; Parini, Clive G. ; Hao, Yuwen

  • Author_Institution
    Sch. of Electron. Eng. & Comput. Sci., Queen Mary, Univ. of London, London, UK
  • Volume
    6
  • Issue
    8
  • fYear
    2012
  • Firstpage
    869
  • Lastpage
    879
  • Abstract
    A quantitative performance evaluation of the millimetre-wave-imaging system developed in the authors´ group is carried out. Two parameters, SNRI (image signal-to-noise ratio) and NEΔR (noise equivalence reflectivity difference) of a few common test targets, a copper slab, a leather covered copper slab and a Perspex slab are used in the evaluation of image qualities, hence to characterise the performance of such a system. In the calculation of these two parameters, a convenient four-step procedure developed by the authors is used. For the evaluation of the resolution of the millimetre-wave-imaging system, an indirect approach is used, in which the imager point spread function (PSF) is estimated based on the measurement data of a knife edge. From the imager PSF the imager resolution is calculated. All these parameters have quantitative values and can be used to make performance comparisons.
  • Keywords
    image resolution; millimetre wave imaging; optical transfer function; reflectivity; NEΔR; Perspex slab; SNRI; frequency 95 GHz; image quality; image resolution; image signal-to-noise ratio; imager PSF; imager point spread function; leather covered copper slab; measurement data; millimetre-wave-imaging system; noise equivalence reflectivity difference; quantitative performance evaluation;
  • fLanguage
    English
  • Journal_Title
    Microwaves, Antennas & Propagation, IET
  • Publisher
    iet
  • ISSN
    1751-8725
  • Type

    jour

  • DOI
    10.1049/iet-map.2011.0581
  • Filename
    6235256