DocumentCode :
1554959
Title :
Doubly-fed induction machine differential cascade. II. Verification by test
Author :
Vicatos, M.S. ; Tegopoulos, J.A.
Author_Institution :
Dept. of Electr. Eng., Nat. Tech. Univ. of Athens, Greece
Volume :
14
Issue :
3
fYear :
1999
fDate :
9/1/1999 12:00:00 AM
Firstpage :
367
Lastpage :
372
Abstract :
In this paper, the doubly-fed differential cascade (DFDC) analysis, in the steady state, given in Part I, is verified by tests. The DFDC consists of two similar doubly-fed machines having the corresponding phases of the two rotors connected. Two sources are used to supply the DFDC stators. One is the mains and the other is a variable frequency converter. The DFDC is loaded with two DC machines acting as brakes. Operations similar to the ones required to provide propulsion to a vehicle are simulated. Variable speed and direction, when the vehicle is moving on a straight course, is simulated by varying the frequency of the frequency converter. Vehicle turn is simulated by distributing the load on the two machines. A nonmoving vehicle, held on a ramp by the DFDC developed torque, is simulated by applying the same frequency to both machines. The experimental results are compared with the results from the analysis
Keywords :
AC-AC power convertors; electric propulsion; electric vehicles; frequency convertors; induction motors; machine theory; rotors; stators; traction motors; doubly-fed induction motor differential cascade; electric vehicle traction drives; experimental results; mains supply; motor loading; rotor phase connections; stators; variable frequency converter; verification tests; DC machines; Frequency conversion; Induction machines; Propulsion; Stators; Synchronous generators; Testing; Torque; Vehicles; Voltage control;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.790884
Filename :
790884