Title :
Electrical characterisation of domestic refrigeration compressors
Author :
Kattakayam, T.A. ; Srinivasan, K.
Author_Institution :
Dept. of Mech. Eng., Indian Inst. of Sci., Bangalore, India
fDate :
5/1/1997 12:00:00 AM
Abstract :
The results of a study on electrical characteristics of hermetic compressor motors used in domestic refrigerators are described. The voltage and current waveforms during start and run states have been investigated for sinusoidal, near square wave and near triangular wave input voltages in the range 170-260 V. An instrumentation system based on an ADC/DAC plug-in card in a personal computer is developed for this purpose. It is deduced that through a considerable redesign of the windings the optimal point of operation corresponding to nominal supply voltage and an improvement in the power factor can be achieved
Keywords :
compressors; induction motors; power factor; refrigerators; starting; wave analysers; waveform analysis; 170 to 260 V; ADC/DAC plug-in card; current waveforms; domestic refrigeration compressors; electrical characterisation; energy efficiency; hermetic compressor motors; induction motor; instrumentation system; near square wave input voltages; near triangular wave input voltages; nominal supply voltage; optimal point of operation; power factor; sinusoidal input voltages; start and run states; starting transient; voltage waveforms;
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
DOI :
10.1049/ip-smt:19970936