DocumentCode
1555593
Title
CdZnTe Focal Plane Polarimetric Performances for a Laue Lens Point Spread Function
Author
de Campos, J.B. ; Silva, R. M Curado da ; Gloster, C.P. ; Pisa, Alessandro ; Caroli, E. ; Stephen, J.B. ; Frontera, F.
Author_Institution
LIP—Laboratório de Instrumentação e Física Experimental de Partículas, Department of Physics, University of Coimbra, Coimbra, Portugal
Volume
59
Issue
4
fYear
2012
Firstpage
1582
Lastpage
1590
Abstract
To date in astrophysics, X- and
-ray celestial emissions have been studied almost exclusively through spectral and timing variability analysis. By measuring the angle and degree of linear polarization of the detected radiation, it is possible to double the number of observational parameters, allowing better discrimination between different astrophysical models. Therefore, future
-ray telescope instrumentation should include the capability to perform high sensitivity polarimetric measurements. This idea has recently become even more appealing in the perspective of new very sensitive
-ray focusing missions equipped with a CdZnTe focal plane, such as the Gamma-Ray Imager and DUAL missions submitted to the European Space Agency\´s Cosmic Vision calls. By combining the most recent simulation developments and the latest experimental results we present the best polarization assessment so far of such a CdZnTe focal plane when coupled to wide band-pass Laue optics (up to 1 MeV). Firstly, the Laue lens response to different source types (Crab type and monochromatic) was simulated by a Monte Carlo code generating a characteristic PSF (point spread function). Afterwards this PSF served as the input to the focal plane mass model simulation. We have calculated the respective modulation
factor for on- and off-axis (2\´) sources. Finally, experimental polarimetric performances of a CdZnTe prototype operating together with Laue lens crystal samples, tested at the European Synchrotron Radiation Facility, validated the focal plane simulation results (
to 0.40, 200 keV to 600 keV range). A minimum detectable polarization- of 2%
was estimated for a 100 mCrab, type source, which is compatible with the high polarimetric sensitivity required for space
-ray polarimetry.
Keywords
Crystals; Detectors; Focusing; Instruments; Lenses; Modulation; Photonics; Astrophysics; Laue lens; gamma-ray detection; polarimetry; semiconductor radiation detectors;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2012.2201752
Filename
6236253